Research monograph

TB-500

A common name with an identity problem. This page distinguishes the acetylated seven-residue fragment examined in primary studies from full-length thymosin beta-4, and explains why a vial name alone cannot connect a lot to that literature.

What is TB-500?

TB-500 is not a sufficiently precise chemical specification on its own. The FDA’s 2026 background evaluation describes the free base as an N-terminally acetylated, seven-amino-acid fragment of thymosin beta-4, corresponding to residues 17–23: Ac-LKKTETQ. It also states that the common name has been used commercially for different salts, derivatives and active moieties. The common name alone does not distinguish those reference substances.[1]

Full-length thymosin beta-4 is a 43-residue peptide, not the seven-residue fragment. Non-acetylated LKKTETQ is another distinct experimental material. Studies on the full-length peptide or the unmodified segment are not direct evidence for Ac-LKKTETQ. The studies below explicitly concerned the acetylated fragment. Their findings concern those documented study materials, not an unidentified catalog lot.[1][4]

Acetylation and an acetate salt are different things. The Ac- in Ac-LKKTETQ is a covalent N-terminal modification. An acetate counter-ion describes a salt form of that peptide. FDA evaluates the free base and acetate separately and notes inconsistent identifiers in submitted documentation. Neither a catalog strength nor the label TB-500 resolves these distinctions.[1]

Research focus: identification, metabolites and model limits

Esposito and colleagues, 2012: the researchers identified the N-terminally acetylated 17–23 fragment in a preparation labelled TB-500 using HPLC with high-resolution mass spectrometry. They also synthesised Ac-LKKTETQ and proposed a triple-quadrupole LC-MS strategy for its detection in plasma and urine. The measured result was chemical identification in the tested preparation, not a biological response. It does not establish the composition of every product subsequently sold under that name.[2]

Ho and colleagues, 2012: this study examined Ac-LKKTETQ and its metabolites in equine urine and plasma. Identification used retention times and relative abundances of major product ions. The authors reported detection and confirmation at 0.02 ng/mL in plasma and 0.01 ng/mL in urine, and confirmed the parent and metabolites in their samples. Those were matrix-specific analytical capabilities, not evidence of a tissue response or a validation of sensitivity in another matrix or instrument.[3]

Rahaman and colleagues, 2024: the investigators developed a UHPLC–Orbitrap MS/MS method using synthesised authentic standards, with metabolism experiments in human serum, enzyme systems and rats. Ac-LK had the highest measured concentration in rat urine over the first 0–6-hour interval; Ac-LKK remained detectable up to 72 hours. Those were metabolite-detection findings in the reported experiment, not a universal persistence period or evidence of storage stability for a laboratory solution.[4]

The same 2024 study screened the parent and metabolites in fibroblast cytotoxicity and scratch-closure experiments. Only Ac-LKKTE showed a significant closure response relative to the control; the parent TB-500 did not. No cytotoxicity was observed under the tested conditions. The distinction between a parent peptide and a metabolite is central: a metabolite result cannot be attributed to the parent. A culture assay also does not establish an outcome in an intact organism or general safety outside its tested conditions.[4]

The three studies reported chemical identification and metabolite measurements in their stated materials and models. They did not establish the identity of an unrelated catalog lot. The parent peptide and the metabolites were separate analytes; a reported metabolite result was not a measurement of the parent.[2][3][4]

Specifications

Reference identifiers: acetylated fragment, not a lot assignment

These identifiers describe Ac-LKKTETQ, the seven-residue free-base reference in the FDA evaluation. They do not establish whether a catalog lot is this fragment, full-length thymosin beta-4, or a salt. Acetate is a separate form; no acetate CAS is assigned here.

Sequence (fragment reference)
Ac-Leu-Lys-Lys-Thr-Glu-Thr-Gln-OH (Ac-LKKTETQ) [1]
CAS (fragment free base)
885340-08-9 [1]
UNII (fragment free base)
QHK6Z47GTG [1]
Molecular formula (fragment free base)
C38H68N10O14 [1]
Molecular weight (fragment free base)
889.01 g/mol [1]Reference value reported in FDA Table 1, not a measurement of supplied material

Supplied catalog material

From the catalog product specification. Salt form and counter-ion identity of the supplied material are not verified on this page.

Salt form
Not verified — see lot documentation
Form
Lyophilized powder, single vial
Purity
≥99% purity per third-party Certificate of Analysis
Storage (sealed)
Sealed storage: −20 °C for long-term storage; 2–8 °C acceptable for short-term laboratory storage. Protect from light.
Storage (reconstituted)
Solution storage specification: 2–8 °C. No universal solution shelf life is established.

Material properties and analytical distinctions

HPLC peak-area purity is not peptide content by mass. Counter-ions, water and other non-peptide components can affect a weighed sample without contributing proportionately to its chromatogram. The cited records do not establish identical extraction or adsorption behaviour for the fragment and full-length peptide.

Storage and stability

No universal TB-500 solution shelf life is assigned here: identity, solvent, pH, concentration, container and temperature all matter. Detection of a metabolite in rat urine is not a stability test for a stock solution.

FDA’s background evaluation discusses peptide aggregation and degradation as formulation-dependent analytical concerns. An unchanged nominal concentration or a visually clear solution is not by itself a demonstration of chemical integrity.[1]

Testing: peptide identity and quantitative content

A reference identifier table is not a lot-specific test result. LC-MS can distinguish the very different masses of the fragment and full-length peptide, but a matching intact mass alone does not establish every residue position or modification site. Sequence-sensitive MS/MS and an appropriate reference standard can provide additional identity evidence.

Chromatographic purity, identity and quantitative content answer different questions. An HPLC percentage cannot establish fragment identity or total peptide content. Counter-ion testing is separate from confirming a covalent acetyl group. Sterility, endotoxin and other impurity tests also require their own methods and results.

For the general lot-matching checklist and interpretation of purity, identity and content results, see how to read a certificate of analysis. Available lot records are in the COA library.

Questions about TB-500

Select a question to read its answer.

Q1Is TB-500 necessarily the full 43-residue thymosin beta-4 peptide?

No. The FDA evaluation and the three primary studies cited here describe the seven-residue acetylated fragment Ac-LKKTETQ. The common name is used inconsistently.

Q2Does Ac-LKKTETQ mean that the peptide is an acetate salt?

No. Ac- denotes a covalently attached N-terminal acetyl group. An acetate counter-ion is a separate salt-form issue. The acetylated peptide can be described as a free base or as an acetate form; neither notation establishes the salt form of a supplied lot without lot-specific documentation.

Q3Why are the TB-500 identifiers labelled as a fragment reference?

CAS 885340-08-9 and the 889.01 g/mol value are reported for the acetylated fragment free base in the FDA evaluation. They are not identifiers assigned here to every TB-500-labelled vial. They do not replace lot-specific sequence and salt documentation.

Q4Did the 2024 fibroblast experiment show the same result for TB-500 and Ac-LKKTE?

No. Only the metabolite Ac-LKKTE significantly changed scratch closure relative to the control under the study conditions; parent Ac-LKKTETQ did not. The metabolite and parent are distinct experimental materials, and this culture result does not establish a response in an intact organism.

Q5Are the equine detection limits a TB-500 solution stability specification?

No. They describe detection and confirmation in urine and plasma processed by a particular analytical method. They do not state how long a prepared stock retains its identity or concentration, nor do they validate another laboratory’s extraction or instrument.

References

  1. [1] FDA, 2026. PCAC background evaluation: TB-500-related substances, section II.A and Table 1
  2. [2] Esposito S et al., 2012. Drug Test Anal. DOI 10.1002/dta.1402; PubMed 22962027
  3. [3] Ho EN et al., 2012. J Chromatogr A. PubMed 23084823
  4. [4] Rahaman KA et al., 2024. J Chromatogr B 1235:124033. DOI 10.1016/j.jchromb.2024.124033

Last reviewed 2026-10-22. For laboratory research use only; not for human or veterinary use. Nothing on this page is medical advice.